Connection failed on some nprinting engines

QlikView, all versions. Best Regards, Aug 13, 2018 · The application C:\ProgramFiles\QlikView\Qv. Environment: Qlik NPrinting 17 and newer. com . 5 to 20. besides, I also tried / have below set-up, while not working: 1. Run the command. Hi @vyshali_v. Qlik Sense server. On the Qlik Sense server, open the QMC and click Users. Jan 17, 2019 · The QS central node experienced a restart, and as a result nPrinting lost its connection and led to a scheduled report not running. Application\GOS Reporting. Connection failed on all NPrinting engines. Random failures could be generated by licenses leased from a QlikView server. 9. Check that the QlikView Desktop has an active license for the Windows user that is running the engine service. Enter the Proxy Address and the Sense App ID. Lab setup a) Source environment NPrinting server hostname :Qlikserver1 NPrinting engine hostname: Qlikserver1 Engine connection: QlikServer1_Engine connection - engine and NP server running on the same instance Jun 11, 2018 · Qlik. The Qlik NPrinting Engine creates reports based on information from scheduler. I regenerated and changed the cert's. After giving Qlik sense certificates to the Nprinting, I was going to create a connection but I realized there isn't any connection in Apps menu. Locate mmc. 1 Like. ", so I suggest to check again the firewall settings. 2 - QlikView Desktop must always have a valid license active. Connections are to the Qlik NPrinting Engine, not to the Qlik NPrinting Server. ERROR: System. Feb 15, 2019 · Default paths to exclude are, for example: C:\Program Files\NPrintingServer\NPrinting\Engine and the document storage location. 17763. Delete the NP engine in the NP engine manager under Admin>Engine manager in the NPrinting Web Console. Enter a Qlik NPrinting Engine Name. Server: dedicated machine, 32GB ram, avg used memory 20%. So to that point please check the points mentioned by @Ruggero_Piccoli and check the following for ways to get up to speed on NPrinting. I would start by going to NPrinintg admin console and running verification of connection again. Possible cause The Qlik NPrinting Server URL contains a slash (the character “/”) after the port number. Any missing step (of which there are many) may result in the failures you are seeing. Add the Qlik Sense hub as destination. You need to have an access to Admin console to proceed further. Delay in obtaining a lock on the document because multiple users may be accessing it. Connection Verification: Success. Have easyhook64svc. Lech Dec 10, 2020 · Open the NPrinting Web Console. We would need to have a careful look at the NPrinting Nov 21, 2018 · If a a local copy of the qvw is consistently faster than the server connection, we can conclude that the delay is due to one of the below: Network delay in connecting to the Qlikview Server. Your security settings require certificates to be stored in the user certificates store. Remember to insert the password to send the certificate. Click Add role, ans select RootAdmin from the list. Also try with: - local NP connection c:\nprinting\qvws\myqvw. Apr 27, 2022 · In this case, there is much work to do to accurately configure NPrinting from End to End. Experiencing a serious issue, please contact us by phone. Add the Engine again. Try again. Best Regards, Ruggero Apr 12, 2019 · NPrinting Engine failed to open document. Sometimes tasks fail,sometimes they dont. Dec 6, 2017 · Defect acknowledgement with Nprinting Engine May 2022 SR2, Hope to get some help here. May 11, 2017 · For future reference: this issue was resolved for me by leasing a QlikView Desktop licence on the server. Qlik NPrinting Engine service logout failure; Qlik NPrinting messaging service (RabbitMQ) start up and connection problems; Qlik NPrinting RepoService service won't start; Firefox browsers not working with Kerberos authentication; Connection timeouts and long running tasks; Connection status not shown in Qlik NPrinting web console; Connection Feb 1, 2017 · use the hostname ie: qlikserver1 or the fully qualified domain name of the Qlik NPrinting server. Connection Type: Local. If a task is already in progress on the same connection, the status is not shown straight away. NavigatorDiedException: Navigator navigator=qlikview;documentpath=\\*****;qlikviewversion=12. Dec 19, 2023 · In some rare circumstances, pressing the Verify connection button will cause the screen to freeze on the “Initializing…” status and the spinning wheel cursor. Right click and open file location. Exceptions. qvw. -Qlikview NPrinting Web Engine. Sep 1, 2020 · Cache generation failed: NPrinting Engine(s) failed to open document: - AFTER WINDOWS UPDATE. More information on exclusions under Qlik NPrinting Server and Designer Anti Virus Folder Exclusions. Able to open Qlikview desktop on NPrinting server and open an app via 'open in server'. -Qlikview NPrinting Engine. Do the following: From the Admin menu, select Engine manager. ) * Pressing Run verification results in Verification successful. Engine 18. Jun 28, 2018 · Hi, 1 - triggers are not supported. 2023-06-15 12:07 PM. At least one engine must be installed. Call Us. InteropServices. The Qlik Sense certificates did not export properly. 29. Click the Next button. Create a Publish task and then specify a Qlik NPrinting app, reports, users, schedule, and the hub as a destination. 3-restart the services, one at a time in the reverse order as above, starting with the rabitt MQ. Jan 14, 2019 · 2. Shooting. Connection unsuccessful on choose NPrinting engines. -Qlikview NPrinting Repo Service. ie: if your Qlik Sense server name is QS1, prepend the file client certificate file name as follows: QS1client. Hopefully someone can assist please. Do NOT use an IP to avoid issues where DHCP may be in play rather than static IPs. For Data Integration related issues please refer to your onboarding documentation for current phone number. In response to vyshali_v. Delete the reinstalled Engine. There are several way to resolve a Warning, Error, or Connection failed status. Until start, open of connection you what to troubleshoot, and click the Run verification button Oct 3, 2022 · This happens when a Qlik NPrinting Engine goes offline and Verify connection is pressed before the Qlik NPrinting Scheduler is aware that it is offline. A Qlik NPrinting engine will spawn one or more QV. Restart Scheduler / engine services. Oct 10, 2023 · Check your Qlik Sense server and or QlikView server at the time the Nprinting task fails to ensure those servers are working properly. This will give Jul 1, 2022 · I have previously connected to this app from NPrinting so dont believe the issue is related to unsupported chart objects in the app. qlik. Metadate reloads fail Connection verification fails at validating the installed certificates The NPrinting Engine logs read: Failed to open a resolver for connection navigator=htt Jan 17, 2019 · Qlik. qvw " a mapped network path?If yes, remember that mapped network drivers are not supported. Sometimes its the cache refreshes that fail, sometimes end user reports. A Warning connection status with the message One or more engines are not working happens in a multi-engine environment when the connection fails in one of the engines. The app I used as an example didnt have any section access. pfx (Naming of this file May 12, 2017 · Tell your admin that there should be NPrinting account which can be used with NPrinitng login - the login would be an email and password was created during NPrinting installation. ie: qlikserver1. Is there an additional setting that would need to be changed in the report that after this connection change is made to allow it to send to all recipients? Oct 20, 2020 · The other possibility is that you need to. Other engines may be working correctly on the same connection, or have not tried to open the connection yet. Mar 23, 2016 · Solved: Hello everybody, Please I need your Help!. 2. 19, want to upgrade the Nprinting from 17. You must remove them from the QlikView documents connected with Qlik NPrinting. Testing and troubleshooting. do NOT use a password. png image failed. I checked connection connecting to Qliksense app id and Verified conncection, every thing looks fine. As an alternative check the QlikView server configuration to be sure Jul 4, 2018 · Qlik NPrinting November 2017. However, the Qlik NPrinting web console will not read them. exe processes to handle these connections. Tags: NPrinting Connection failed to connect to QlikView server. This happens when a Qlik NPrinting® Engine goes offline and Verify connection is pressed before the Qlik NPrinting® Scheduler is aware that it is offline. Sep 26, 2019 · 1 Solution. Engine. Connections must be added after the initial creation of a Qlik NPrinting app. Have several connections to the Sense server for Apps in stream Everyone. In the Name box, enter a name for the connection. This connection, generating The Qlik NPrinting Server URL entered during the Qlik NPrinting On-Demand Add-on installation must be formatted correctly to be recognized. Mar 17, 2020 · Go to Trusted root Certification Authorities then delete the certificate NPrinting-CA. Consumer. Also, make sure you do not have any unsupported items blocking the normal opening of the QVW. Go to start and search for "mmc". Section Access in document: No. pfx' with a suitable name. Qlik NPrinting Server and Designer Anti Virus Folder Exclusions the report in Qlik NPrinting Designer. Messages. Verification is okay and Connection status successful on all NPrinting engines (only one, single server installation). Could not open connection to host, on port 4242: Connection failed. Qlik Sense April 2018. Click the “Create Connection” button. All but one working? They use the same Proxy-adress and user, copied Sense app ID from Hub. Is it because a step hasn't been done correctly or because Nprinting didn't Feb 7, 2023 · Make sure to publish all sheets and sheet objects required for NPrinting reporting purposes (speak to each app owner/developer and ensure all objects are published) Duplicate and export the App (this will remove any private sheets remaining) Create a a test NP connection (in the same NP App) to the duplicate Qlik Sense app. 40. Frank_S. We would like to show you a description here but the site won’t allow us. Feb 21, 2019 · QlikNprinting services are all unable to start with the following errors Errors: The connection status is set the first time you open a QlikView document to generate the connection cache, or a report. A list of checks performed will appear under Details. If the issue is solved please mark the answer with Accept as Solution. * Under Admin > Task Executions I see: Cache rebuild task for connection Invoiced Data | Generate connection cache | Failed | 100% | <time> | <time> Jun 5, 2019 · NP scheduler or Messenger (RabbitMQ) Service not starting, NPrinting Run Verification Designer Preview issue, NPrinting Engine Offline. Jun 19, 2018 · (by this do you mean is the NPrinting installed on the same server as Qlik Sense? They are two separate servers. By the way, I manage to generate cache sometimes, but then I am facing another issue when trying to preview or generate report: resolution ended unsuccessfully with exception System. Reload Trigger: Daily You have added your Qlik Sense certificates to the correct folder on your Qlik NPrinting Server and Qlik NPrinting Engine machines. Verify your connection. Adding a new engine. Qlik. To be on the safe side, I've created new app with a single table in it with 94 rows of data (I've blurred out the Proxy Address and Identity but happy to show these offline if needed) I'm seeing this message Mar 8, 2016 · 1-delete the connection to your . Runtime. 0 Qlik. Symptoms: Scenario A: When installing or upgrading the Run Verification will not run after creating an App Connection. The task is queued and you must wait a short time before the status is updated. Nov 2, 2023 · Dedicated NPrinting Server & Engine Service Accoun - Qlik Community - 1716056 Please remember hit the 'Like' button and for helpful answers and resolutions, click on the 'Accept As Solution' button. exe file in its installation path. This happens when a Qlik NPrinting Engine goes offline and Verify connection is pressed before the Qlik NPrinting Scheduler is aware that it is offline. Its not always the same tasks that fail. These users are selected for the report with error, in addition to others who do not have the domain configured Jan 2, 2019 · 2019-01-02 07:39 PM. Aug 8, 2023 · Execution for task [number] failed for an exception RabbitMQ. ie: " NP_App_QSserver-2 ". dll", by calling, but the antivirus is blocking it. The Qlik NPrinting Server also coordinates multiple reporting engines installed on different nodes to distribute the workload and to create a high availability environment. Uninstall the NPrinting engine. These must be members of the same domain. But the Nprinting task log and Engine log would be the first place to start. Best Regards, Ruggero. Proposed action Remove the slash after the Qlik NPrinting Server URL and try again. - Click on 'Run verification'. 2. cs:line 34↓↓ at May 9, 2023 · Error: NPrinting Engine(s) failed to open document, Check connection page for connection status. exe) instance on the NPrinting Engine node with no issues, but when NPrinting connects to the document it consumes all the resources of the QlikView server. Than insert the credentials of the user running the Engine service and open the source QVWs. -Rabitt MQ. Please mention what you are experiencing to your NPrinting server administrator. Warning: One or more engines are not working. Consider that the generation of metadata is different in NPrinting 16 and 17. 3. Jun 16, 2019 · These errors may be caused by one of the following: We suggest: Add report filters to reduce the report and data size and try again. To start, open the connection you want to troubleshoot, and click the Run verification button. If a test fails, you will see a red X next to that item in the list. The Qlik NPrinting Engine logs read: For information on how to locate the log files, see: How to collect the Qlik NPrinting Platform Log Files. Please remember hit the 'Like' button and for helpful answers and resolutions, click on the 'Accept As Solution' button. Given the same qvw file (no changes), one time fails and the next succeeds: Heres my spec: NPrinting version: Sept 2018 SR2. All the task executions are failed in Nprinting. NPrinting Engine(s) failed to open document: Jan 9, 2020 · I have created a report in Nprinting. Thither live several pattern to resolve a Warning, Error, or Connection failed status. qvw Oct 22, 2019 · Generally, a solution for this problem, is to simplify the formulas or move them to the script. Next, reinstall the NPrinting Engine software (type/document the certificate password used as you will need it in the next step. check the 'include secret key' checkbox and. The Qlik NPrinting Repository Service installer appears. exe is attempted to load the library "C:\Program Files\NPrintingServer\NPrinting\Engine\EasyHook64. Qlik NPrinting connects to QlikView applications in one of three ways: • Local connection: Uses a UNC file path to open a copy of the QVW using the hardware resources of the Qlik NPrinting engine. Firewall inbound allow port 4243, outbound allow 4242, 4747, 4343. Possible cause. qvf, to test your Jun 11, 2018 · The log says " Valid Sense Engine qlik-sense is not reachable on port 4747. Jan 31, 2019 · I also suggest upgrading to the latest version of NPrinting to leverage vastly improved logging, bug fixes and performance enhancements. 4. Feb 6, 2024 · You must allocate a Named CAL to the user who runs the Qlik NPrinting Engine service or activate a locali license code. QWV it will not be a Personal Edition that is not supported. Oct 24, 2017 · for connection to QlikView app. It can take up to 20 seconds before the Qlik NPrinting Scheduler determines the offline status of a Qlik NPrinting Engine. Jun 11, 2018 · I started the normal process this morning, creating an app, creating a connection, testing and generating the metadata. If the response is: Connecting to yourservernamehere. Re-install the NPrinting engine (ensure the engine is the same version as the NP server) In the NP web console, delete your NPrinting Engine entity, recreate it, then resend the certificates to solve the issue. Those ways will warranty that when Qlik NPrinting Engine opens the local QlikView Desktop to access the . I am trying to create a connection to qlikview server, for load a document qvw, but when the - 1059380 Apr 18, 2019 · If you've encountered issues making a connection, here are some articles that might help: How to Resolve the NPrinting 17, 18, 19 and Higher Version Hangs, Purged Connection and Verification Errors Finetuning and preparing your NPrinting 17+ Deployment for use with QlikView and Qlik Sense Aug 19, 2021 · This is typically caused when an 'On Open' trigger is used in the QWV. May 25, 2021 · We have tried to install the Nprinting version 20. I am using NPrinting September 2017. Logging on to the server with the nprinting service account. qvw Connection successful on all NPrinting engines. 5. Reload the connection. apps. Select Run as a different user, and then enter the credentials of the Qlik NPrinting Windows user. Nov 6, 2023 · For another report (only related to this report by the application) we need to implement "Section Access" process in order to filter data for some users, so we need to set the domain for these users. There is no limit to the number of connections you can add to an app. . Support. • Server connection: May 21, 2017 · I am having a problem of Engine offline, after added machine name (QVSRV) to the engine address, the engine status remains offline. An NPrinting engine will spawn one or more QV. You can add new connections, or modify existing connections for each Qlik NPrinting app. Create a new NP connection and use the Virtual Proxy Address for the new target Qlik Sense server. ContentResolverFactory. NPrinting connects to QlikView applications in one of three ways: • Local connection: Uses a UNC file path to open a copy of the QVW using the hardware resources of the NP Engine. Hi, It is quite straight forward - your engine cannot open a document. telnet yourservernamehere. Apr 7, 2021 · Description of Issue NPrinting Connections fail regularly or intermittently when attempting to reload NPrinting Connection in the NPrinting web console. Client. But when i included 2 more reports to that task, it is throwing me the below error: Failed generation of report 28. When the installation completes, click the Close button to exit the Microsoft C++ Redistributable installer. Jun 11, 2018 · Qlik. If you do not see it, then it has not been published to the NP service account. hope this helps. for user abc . I've installed the NPrinting server and Engine and Qlik sense on the same machine. QVWs specific for reporting. If you change the size or layout of the table in Qlik Sense, you will need to reload your Qlik Sense connection cache in Qlik NPrinting. If having issues connecting to multiple Qlik Connection successful on all NPrinting engines. Proposed action. exe excluded from the Antivirus detection. The document may be getting reloaded at that time. After you can switch on the firewall again. https://qliksupport Jun 19, 2018 · Open a Windows Command prompt. cs:line 34↓↓ at Jun 15, 2023 · Support. 0) I can also log onto the NPrinting server and open the Qlik Sense apps via a browser. This is where things went sour and the Cache Generation failed on this new connection, strangely all other models cache generation is still working so Im really unsure where to begin. Exporting the certificates from the QMC. 2019-10-02 11:01 AM. Enter a Description. NPrinting. Feb 28, 2019 · If QVP connection, do File>Open in Server and try to open the QVW while logged on as the NP service account. Give credentials for the user with which Qlik Sense services are running. 0 0 0 0 0 Failed to open a resolver for connection navigator=qliksense Some reports failed to generate: Aug 4, 2017 · Hi, Is "QlikView is not able to open the document D:\SD_QlikviewSource\2. You can use our Qlik Sense sample app, Beginner’s tutorial. If the Qlik NPrinting scheduler service and Qlik NPrinting Engine are installed on the same computer, you only need to install the certificates once. Next, from the App drop-down list, select the app you’ve just created. • Server connection: A Qlik NPrinting Engine that is already connected to a Qlik NPrinting scheduler service will appear as offline, and cannot be used by the new connection. 1. GOSreporting\1. Mar 4, 2019 · - Target environment: 1 NPrinting server hosting the repository database, and 2 NPrinting engine servers running 1 engine each. Resolution: Configure the antivirus according to Qlik documentation. When you create a connection to a Qlik Sense app, use the Verify connection button to check that your connection is valid. It can be helpful to upgrade to the latest NPrinting release. Reporting. Each and every app runs successfully with the verification : but then fails with the metadata load : Engine logs : Failed to open a resolver for connection navigator Aug 3, 2023 · After the latest Windows update (KB5028168, KB5028855, Servicing Stack 10. then the port is blocked or DNS records for the name of the machine are not correct. This new feature makes the upgrade procedure easier to maintain. - Click the Connection name. Get(Guid engineId, String connectionString, IRequestBuffer buffer, Int32 initialMaxBatchSize, CancellationToken cancToken) in c:\Jws\release-18. WebException: Unable to connect to the remote server ---> System. May 5, 2020 · Next, If June 2019 NPrinting or later versions are is in use, do the following: Navigate to the exported certificates location on the QS server and rename the exported file ' client. Isolate the task that is running and run just the task without any other simultaneous tasks executing at the same time to verify if this is resource related. Jul 24, 2019 · This just started happening a few days ago when we switched from a local connection to the QVP connection. In case you can create some . 20000 process died or has been terminated and can't be used anymore to resolve requests ---> System. We have checked at the However, below steps helped me to get rid of that. Open the Engine manager in the Web Console. exe, press shift and right click, select run as different user. To sum up, The NPrinting engine service account, the NPrinting server and the. Reviewing the event log 'nprinting_engine_ceg' file shows these errors: Failed to ping Sense while keeping session alive. It's possible at this point that your system or systems may be locked up with Windows memory leaks and open/running executions. There can be multiple reasons for it, for example: Section access was introduced, QVW/QVF Document was renamed or changed location. Select Destinations and then select Hub. qvew. QlikView application. 19 , but we have facing some issue with the Nprinting system, Specifically the connection page is not able to open; we are able to login the web console but it will be disabled once we try to go through the Connection page. Restart your NPrinting and QV servers outside of Production hours. Keep Source Format option does not keep Excel merged cells May 25, 2021 · On the main menu, click the Apps drop-down, and click “Connections. ”. Jan 14, 2019 · When NPrinting reports are re-ran after failures, they usually run fine. Mar 22, 2021 · The NPrinting software runs on a server which also runs QDS and also our data warehouse SQL Server and ETL platforms, but has plenty of available resource. 2-stop the services in the following order: -QlikView NPrinting Scheduler. BR, Bernd. Net. Dec 15, 2023 · In some rare circumstances, pressing the Verify connection button will cause the screen to freeze on the “Initializing…” status and the spinning wheel cursor. Net Jul 1, 2022 · Hi Lech Thanks for the reply. The Verify connection under Apps / Connections runs all green. Select the user that you created in step 1 from the list, and click Edit. Scenario B: The Engine Service stops immediately after a restart or it works but the Engine Do the following: Log into Qlik NPrinting as a user with Publish tasks authorization. It works during the Preview and when task is run. Click Add engine. . BrokerUnreachableException: None of the specified endpoints were reachable. May 12, 2020 · ERROR: Qlik. 747 Views. New versioning system Qlik NPrinting has a new versioning system that complies with the company standard. Troubleshooting QlikView Desktop verification errors The connection parameters are formally valid. If local or network connection, do File>Open and try to open the QVW while logged on as the NP service account. Exception: Export from QlikView of chart Document\TX191 as . com 4242. Defects that can cause a slow down in the generation of metadata are fixed in each new release. If you are connecting Qlik NPrinting to Qlik Sense, you must assign RootAdmin authorization to the user that runs the Qlik NPrinting Engine service. Certificates must also be installed on all Qlik NPrinting Engine computers in order to create connections to Qlik Sense apps. NPrinting Select the check box to agree to the license terms and click the Install button. COMException: The remote procedure call failed. Check logs for details. QlikView Personal Edition is not May 26, 2023 · In the Engine logs there are Authentication Failed errors. Save your connection to load the metadata for the first time. This is just one of the unsupported items you need to check for and address but there are several you may need to address as per the article in the link below: Nprinting: Unsupported QlikView Document items, System Configurations and other limitations. 15. 3. Do the following: Mar 2, 2020 · A large QlikView document (. 8. Engine 23. Troubleshooting. Also ensure that your domain account used to run the NPrinting services is rootadmin on the Qlik Sense server. Re-installation of an existing Qlik NPrinting Engines Jira issue ID: OP-8043 If you uninstall and then reinstall an existing Qlik NPrinting Engine, you must re-activate it: 1. Oct 27, 2021 · Connection doesn't show in NPrinting. Check the engine logs on the computers where the The Connection status column shows one of the following values for each configured connection: Connection successful on all NPrinting engines. Enter a password for the repository database. 20. Each and every app runs successfully with the verification : but then fails with the metadata load : Engine logs : Failed to open a resolver for connection navigator. Find the Qv. Qlik Sense version is May 2022 Patch 3. Exception: Object JMjSeES of Sense app 123 failed to render. Follow @Lech_Miszkiewicz 's suggestion and login via RDP in the Qlik NPrinting server with the Windows user that runs the Engine service ahd try to open the document on QlikView server with the local QlikView Desktop. The NPrinting Engine log will contain the following error: Status(StatusCode=Unavailable, Detail="Connect Failed") Environment NPrinting 201 Mar 22, 2021 · The NPrinting software runs on a server which also runs QDS and also our data warehouse SQL Server and ETL platforms, but has plenty of available resource. qvw file) may be opened manually from the QlikView Desktop (qv. Qlik NPrinting Engine. For for information, see the following articles as well. Hold down SHIFT, and then right-click the file. - You can then see the details: 6,010 Views. Apr 6, 2021 · The following symptoms can be observed: Tasks in NPrinting fail with ERROR: NPrinting Engine failed to open document. Qlik Sense. Typically, a status update takes 15-30 seconds When you create a connection to a QlikView document, use the Verify connection button to check that your connection is valid. qvw - QVP connection ie: qvp:\\myqlikserver\myqvw. If you are the NP admin, then I suggest starting a support case in order to investigate the issue in greater detail. 0. You need the central node address for the Qlik Sense server. 4640) the NPrinting cannot generate cache. exe file, do a right click while keeping CTRL and SHIFT pressed and select "Run as a different user". com. Create a test report and preview. Jun 14, 2022 · One way to check is to log on as the NP service account on the NPrinting Server/Engine computer, OPen the QV desktop, do 'file>open in server' and attempt to open Panorama_NPrinting. Bring a copy of the app onto the Qlik NPrinting server Jun 18, 2020 · Critical Issues. May 30, 2023 · In some rare circumstances, pressing the Verify connection button will cause the screen to freeze on the “Initializing…” status and the spinning wheel cursor. You can view any errors when you verify the connection: - Apps > Connections. Feb 28, 2019 · 2. Just to try, you could disable the firewall on both Qlik Sense Engine computer and Qlik NPrinting Engine computer and see what happens. For example, enter Engine 2. Jan 22, 2019 · On the Qlik NPrinting Engine computer, find the Qv. Nprinting is version May 2022 ( Version: 22. x\server\NPrinting\src\Engine\Consumer\ContentResolverFactory. Create a new NP App. After that, select Qlik Sense as the source. ch ju vy di go fb ji fw dv sn